34E11Z3A1-1A11 ITT Alcon ITT Alcon Solenoid Valve 34E11Z3A1-1A81, 2 port , NC, 230 V ac, 3/4in

Part Nnumber
34E11Z3A1-1A11
Description
ITT Alcon Solenoid Valve 34E11Z3A1-1A81, 2 port , NC, 230 V ac, 3/4in
Producer
ITT Alcon
Basic price
116,73 EUR

The product with part number 34E11Z3A1-1A11 (ITT Alcon Solenoid Valve 34E11Z3A1-1A81, 2 port , NC, 230 V ac, 3/4in) is from company ITT Alcon and distributed with basic unit price 116,73 EUR. Minimal order quantity is 1 pc.


Body MaterialAluminium Connection3/4 in BSPT Female Connection GenderFemale Connection Size3/4in Default Valve PositionNC Flow Factor Kv12.9m³/h Maximum Operating Temperature+60°C Maximum Working Pressure1bar Minimum Operating Temperature0°C Number of Ports2 Operating Temperature Range0 → +60 °C Orifice Diameter19mm SeriesGB Suitable ApplicationsAutomatic Burner, Fire Protection System, Low Pressure Natural Gas Supply Voltage230 V ac Thread Standard or Connection TypeBSPT Type2/2 Product Details Ventilation Interlock Panel - Gas Safety System 2 The Gas Safety System 2 (GSS2) is a ventilation interlock system with built-in current monitoring. It is designed specifically for use in commercial kitchens to meet BS6173:2001, which is now a recogognised standard in the catering industry. This panel is to be used when the kitchen appliances do have a flame failure device, therefore gas proving is not a requirement.,The GSS2 acts as an interlock between the ventilation system and the gas solenoid valve. It has a built-in power monitor which is a method used for interlocking a kitchen gas supply with the ventilation system.,As an alternative to pressure differential switches the GSS2 is designed to monitor the electrical current going to a ventilation fan. When the fan is switched ON and there is sufficient current being drawn by the fan, the GSS2 panel receives a signal to indicate that the fans are operating. Turning the key switch to ON will open the gas solenoid valve. If the fans should fail the "Fan Fault" LED on the GSS2 panel will illuminate and the gas solenoid valve will be commanded to close.,When there is a fan fault, the supply or extract fan LED on the GSS2 panel will flash. This provides information on which fan has failed.,Installation of the GSS2 is simple with no calibration required. Straightforward volt free wiring is required for all BMS and remote emergency stops. CORGI Registered installer is required for the gas solenoid valve installation. Allows Compliance with BS6173: 2001 for commercial kitchensClear LED display for system indicationsReliable method of interlock, with no moving partsBMS Terminals Normally Closed or Normally Open and commonWill accept remote emergency shut-off buttonsIncorporated emergency gas shut down panic buttonSimple installation and suitable for wall mounting Note Not recommended for use with belt driven fans Fan Controllers


Following Parts

Random Products

(keyword 34E11Z3A1-1A11 ITT Alcon ITT Alcon Solenoid Valve 34E11Z3A1-1A81, 2 port , NC, 230 V ac, 3/4in)
© 2015 Industry Server